PROPERTY INSPECTION REPORT

Prepared For:
(Name of Client)
Concerning: 123 Main, , TX
(Address or Other Identification of Inspected Property)
By: Jason W Newman TREC #24331 / AmeriSpec Inspection Services 1/11/2021
(Name and License Number of Inspector) (Date)
(Name, License Number of Sponsoring Inspector)

PURPOSE, LIMITATIONS AND INSPECTOR / CLIENT RESPONSIBILITIES

This property inspection report may include an inspection agreement (contract), addenda, and other information related to property conditions. If any item or comment is unclear, you should ask the inspector to clarify the findings. It is important that you carefully read ALL of this information.

This inspection is subject to the rules (“Rules”) of the Texas Real Estate Commission (“TREC”), which can be found at www.trec.texas.gov.

The TREC Standards of Practice (Sections 535.227-535.233 of the Rules) are the minimum standard for inspections by TREC Licensed inspectors. An inspection addresses only those components and conditions that are present, visible, and accessible at the time of the inspection. While there may be other parts, components or systems present, only those items specifically noted as being inspected were inspected. The inspector is NOT required to turn on decommissioned equipment, systems, utility services or apply an open flame or light a pilot to operate any appliance. The inspector is NOT required to climb over obstacles, move furnishings or stored items. The inspection report may address issues that are code-based or may refer to a particular code; however, this is NOT a code compliance inspection and does NOT verify compliance with manufacturer’s installation instructions. The inspection does NOT imply insurability or warrantability of the structure or its components. Although some safety issues may be addressed in this report, this inspection is NOT a safety/code inspection, and the inspector is NOT required to identify all potential hazards.

In this report, the inspector shall indicate, by checking the appropriate boxes on the form, whether each item was inspected, not inspected, not present or deficient and explain the findings in the corresponding section in the body of the report form. The inspector must check the Deficient (D) box if a condition exists that adversely and materially affects the performance of a system or component or constitutes a hazard to life, limb or property as specified by the TREC Standards of Practice. General deficiencies include inoperability, material distress, water penetration, damage, deterioration, missing components, and unsuitable installation. Comments may be provided by the inspector whether or not an item is deemed deficient. The inspector is not required to prioritize or emphasize the importance of one deficiency over another.

Some items reported may be considered life-safety upgrades to the property. For more information, refer to Texas Real Estate Consumer Notice Concerning Recognized Hazards or Deficiencies below.

THIS PROPERTY INSPECTION IS NOT A TECHNICALLY EXHAUSTIVE INSPECTION OF THE STRUCTURE, SYSTEMS OR COMPONENTS. The inspection may not reveal all deficiencies. A real estate inspection helps to reduce some of the risk involved in purchasing a home, but it cannot eliminate these risks, nor can the inspection anticipate future events or changes in performance due to changes in use or occupancy. It is recommended that you obtain as much information as is available about this property, including any seller’s disclosures, previous inspection reports, engineering reports, building/remodeling permits, and reports performed for or by relocation companies, municipal inspection departments, lenders, insurers, and appraisers.

Promulgated by the Texas Real Estate Commission(TREC) P.O. Box 12188, Austin, TX 78711-2188 (512)936-3000

(http:\\www.trec.state.tx.us).

You should also attempt to determine whether repairs, renovation, remodeling, additions, or other such activities have taken place at this property. It is not the inspector’s responsibility to confirm that information obtained from these sources is complete or accurate or that this inspection is consistent with the opinions expressed in previous or future reports.

ITEMS IDENTIFIED IN THE REPORT DO NOT OBLIGATE ANY PARTY TO MAKE REPAIRS OR TAKE OTHER ACTIONS, NOR IS THE PURCHASER REQUIRED TO REQUEST THAT THE SELLER TAKE ANY ACTION. When a deficiency is reported, it is the client’s responsibility to obtain further evaluations and/or cost estimates from qualified service professionals. Any such follow-up should take place prior to the expiration of any time limitations such as option periods.

Evaluations by qualified tradesmen may lead to the discovery of additional deficiencies which may involve additional repair costs. Failure to address deficiencies or comments noted in this report may lead to further damage of the structure or systems and add to the original repair costs. The inspector is not required to provide follow-up services to verify that proper repairs have been made.

Property conditions change with time and use. For example, mechanical devices can fail at any time, plumbing gaskets and seals may crack if the appliance or plumbing fixture is not used often, roof leaks can occur at any time regardless of the apparent condition of the roof, and the performance of the structure and the systems may change due to changes in use or occupancy, effects of weather, etc. These changes or repairs made to the structure after the inspection may render information contained herein obsolete or invalid. This report is provided for the specific benefit of the client named above and is based on observations at the time of the inspection. If you did not hire the inspector yourself, reliance on this report may provide incomplete or outdated information. Repairs, professional opinions or additional inspection reports may affect the meaning of the information in this report. It is recommended that you hire a licensed inspector to perform an inspection to meet your specific needs and to provide you with current information concerning this property.

TEXAS REAL ESTATE CONSUMER NOTICE CONCERNING HAZARDS OR DEFICIENCIES

Each year, Texans sustain property damage and are injured by accidents in the home. While some accidents may not be avoidable, many other accidents, injuries, and deaths may be avoided through the identification and repair of certain hazardous conditions. Examples of such hazards include:

To ensure that consumers are informed of hazards such as these, the Texas Real Estate Commission (TREC) has adopted Standards of Practice requiring licensed inspectors to report these conditions as “Deficient” when performing an inspection for a buyer or seller, if they can be reasonably determined.

These conditions may not have violated building codes or common practices at the time of the construction of the home, or they may have been “grandfathered” because they were present prior to the adoption of codes prohibiting such conditions. While the TREC Standards of Practice do not require inspectors to perform a code compliance inspection, TREC considers the potential for injury or property loss from the hazards addressed in the Standards of Practice to be significant enough to warrant this notice.

Contract forms developed by TREC for use by its real estate licensees also inform the buyer of the right to have the home inspected and can provide an option clause permitting the buyer to terminate the contract within a specified time. Neither the Standards of Practice nor the TREC contract forms require a seller to remedy conditions revealed by an inspection. The decision to correct a hazard or any deficiency identified in an inspection report is left to the parties to the contract for the sale or purchase of the home.

INFORMATION INCLUDED UNDER "ADDITIONAL INFORMATION PROVIDED BY INSPECTOR", OR PROVIDED AS AN ATTACHMENT WITH THE STANDARD FORM, IS NOT REQUIRED BY THE COMMISSION AND MAY CONTAIN CONTRACTUAL TERMS BETWEEN THE INSPECTOR AND YOU, AS THE CLIENT. THE COMMISSION DOES NOT REGULATE CONTRACTUAL TERMS BETWEEN PARTIES. IF YOU DO NOT UNDERSTAND THE EFFECT OF ANY CONTRACTUAL TERM CONTAINED IN THIS SECTION OR ANY ATTACHMENTS, CONSULT AN ATTORNEY.

ADDITIONAL INFORMATION PROVIDED BY INSPECTOR:

Type of building:
Single Family (1 story)

In Attendance:
Customer

Approximate age of building:
10 to 15 Years

Temperature:
60 degrees (F)

Weather:
Cloudy

Ground/Soil surface condition:
Damp

Rain in last 3 days:
No

  

Sq Ft: 2136
Year Built: 2010
Foundation: Slab on grade
Occupied: yes
Utilities On: yes


Occupied : 1
UtilitiesOn : yes

Gate Code :
Ordered By : Buyer's Agent
FSBO :
SquareFeet :
YearBuilt :
Mother In Law Apartment : No
Garage : Attached

Dog in backyard :
Access : Use your supra key
Contract : Inspector to send contract to client
MLS Number : 20211586
BuyerPresent : 1

Top Table of Contents Bottom

Table of Contents

Top Table of Contents Bottom
I = Inspected     NI = Not Inspected     NP = Not Present     D = Deficient    
I NI NP D    
 
I.   Structural Systems
A. Foundations
Type of Foundation(s):   Slab on Grade
Method Used To Inspect Crawlspace:   N/A
Columns or Piers:   N/A
Comments:
(1) Foundation appears to be performing satisfactory.
(2) Homes built with a slab construction may have heating duct work, plumbing, gas, and electrical lines running beneath the slab. As it is impossible to determine position of these items by a visual inspection, they are specifically excluded from the scope of this inspection.
B. Grading and Drainage
Comments:
(1) There are ground drains present at multiple locations and will need periodical cleaning and maintenance.  This is for your information.
B. Item 1(Picture)

(2) There is a negative slope at the rear of home which can cause or contribute to water intrusion or deterioration. Recommend correcting landscape to drain water away from home. Recommend further evaluation by a licensed contractor for corrections prior to close.
B. Item 2(Picture)
B. Item 3(Picture)

(3) The gutters are full of debris in areas and needs to be cleaned. The debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned. We are unable to determine if such conditions exist.
B. Item 4(Picture)

(4) The gutter needs to be tightened against fascia and sealed at the front of home.
B. Item 5(Picture)

(5) The downspout is loose at multiple locations. Loose or leaking gutters can cause deterioration of fascia, soffit or roof edge. It can also cause gutters to pull loose and lead to possible water intrusion. A qualified contractor should inspect and repair as needed.
B. Item 6(Picture)
B. Item 7(Picture)
B. Item 8(Picture)
B. Item 9(Picture)

(6) The downspout needs an extension and a buried drain line to carry water away from the home at the rear of home.  Current system is not performing as intended to collect roof drainage and negative slope drainage. Recommend qualified contractors repair or replace as needed.
B. Item 10(Picture)

(7) Recommend adding dirt back-fill to any low lying areas around the foundation to ensure proper drainage away from the foundation at all times.
B. Item 11(Picture)

C. Roof Covering Materials
Type(s) of Roof Covering:   Asphalt Composition Shingle, Architectural
Roof Viewed From:   Walked roof
Comments:
(1) The roof covering is damaged at the front of home. This damage should be repaired or replaced. A qualified contractor should inspect and repair as needed.
C. Item 1(Picture)
C. Item 2(Picture)
C. Item 3(Picture)
C. Item 4(Picture)
C. Item 5(Picture)

(2) Exposed screws observed at the various locations. Screw heads should be sealed to prevent water penetration. Recommend review by a licensed roofer for corrections prior to close.
C. Item 6(Picture)
C. Item 7(Picture)

D. Roof Structures and Attics
Attic Viewed From:   Walked
Approximate Average Depth of Insulation:   Appoximately 12 inches
Roof Structure Type:   Wood Frame, 2 X 4 Rafters
Roof-Type:   Hip
Comments:
Pull-down stairway is damaged. Recommend review by Licensed/Qualified professional for repair or replacement as necessary.
D. Item 1(Picture)

E. Walls (Interior and Exterior)
Exterior Wall Cladding/Siding:   Brick Veneer, Wood Siding
Wall Structure:   Traditional Wood Frame Construction
Interior Wall Material(s):   Gypsum Board (Drywall)
Comments:
(1) Siding in contact with ground at exterior in areas. Because the siding is in contact with ground it is possible for framing to be deteriorated. We did not inspect behind this siding. Recommend a ground clearance of six to eight inches where possible.
E. Item 1(Picture)
E. Item 2(Picture)

(2) Cracked brick and mortar joints observed at right side. These appear to be caused by common settlement with no differential movement. We recommend professionally repairing  and sealing the affected area to reduce the potential for water infiltration into the home and further displacement.
E. Item 3(Picture)
E. Item 4(Picture)

(3) The Wood trim at the rear of home reveals a hole where looks like a nail was removed. This area should be sealed to prevent moisture intrusion.  A qualified person should repair or replace as needed.
E. Item 5(Picture)

(4) Cosmetic damage such as lack of doorstops and damaged trim was observed.  This is for your information. Repair or replace as needed.
F. Ceilings and Floors
Floor Structure:   Slab
Ceiling Structure:   2 X 6 Joists
Floor Covering(s):   Resilient Flooring
Ceiling Material(s):   Gypsum Board (Drywall)
Comments:
G. Doors (Interior and Exterior)
Exterior Entry Doors:   Wood, Metal Clad
Interior Doors:   Hollow Core
Comments:
(1) Patio door at rear of home is rusted and does not lock at door knob. This is a maintenance issue and is for your information. A qualified person should repair or replace as needed.
G. Item 1(Picture)
G. Item 2(Picture)

(2) Main Entry door frame has a type of fungal growth present.  Recommend removal.
G. Item 3(Picture)

(3) The Garage Door has damaged weather-stripping. This can cause some heat loss in winter and loss of cool air in summer if not corrected. A qualified person should repair or replace as needed.
G. Item 4(Picture)

H. Windows
Windows and Frames Type(s):   Single-hung
Comments:
(1) Damaged and or missing screens observed at the rear of property. Recommend review for replacement as needed.
(2) The window frame is deteriorated at right side (facing front). Further deterioration may occur if not repaired. A qualified contractor should inspect and repair as needed.
H. Item 1(Picture)

I. Stairways (Interior and Exterior)
Comments:
J. Fireplaces and Chimneys
Types of Fireplaces / Wood Stove:   Vented Gas Logs
Chimney Type:   Metal Flue Pipe
Chimney Flue Type:   Metal
Operable Fireplaces:   One
Comments:
(1) It is highly recommended that the chimney(s) be checked by a CSIA (Chimney Safety Institute of America) certified chimney professional prior to closing and cleaned if necessary. NFPA (National Fire Protection Association) 211 recommends what is known as a Level II inspection, including a video scan, by a qualified chimney specialist as part of the home buying process. A Level II inspection may identify problems that exist which cannot be detected during a general home inspection.  All references to a "qualified chimney professional" or "contractor" in this section means a CSIA certified individual.
(2) The wood siding is deteriorated and the chimney chase is loose. Further deterioration may occur if not repaired. A qualified contactor should repair or replace as needed.
J. Item 1(Picture)
J. Item 2(Picture)
J. Item 3(Picture)

(3) Gas logs are present. We recommend using caution when gas logs are used in this fireplace. Always operate per manufactures recommendations and with damper open to allow products of combustion to vent to exterior. Client may wish to consider installing a damper stop for safety.
J. Item 4(Picture)
J. Item 5(Picture)

K. Porches, Balconies, Decks and Carports
Appurtenance:   Covered porch
Comments:
L. Other
Driveway:   Concrete
Walkways:   Concrete
Comments:
(1) We did not inspect any additional buildings. We only inspected the main structure. Deficiencies may exist with these structures or building (s). Our company makes no representation to the condition of these structures or building (s).
(2) Sporadic wood deterioration noted to wood fence boards and framing; this is common with wood fences. We suggest maintenance and repairs be performed, as necessary by qualified personnel.
L. Item 1(Picture)
L. Item 2(Picture)
L. Item 3(Picture)

Top Table of Contents Bottom
I = Inspected     NI = Not Inspected     NP = Not Present     D = Deficient    
I NI NP D    
 
II.   Electrical Systems
Our electrical inspection meets the ASHI standard of practice and is done by sampling visibly accessible wiring and fixtures. Determining the actual capacity of the system requires load calculations, which are not within the scope of this report. Underground circuits and concealed components of the system are not inspected. While age is one factor, most homes have electrical issues created by amateur electricians. We do not move belongings and do not examine every fixture, outlet, wiring run, etc., nor do we remove insulation, or wall coverings. Covers are not removed, with the exception of the cover of the main electrical panel, when this can be done safely and without risking damage to finish. Much of the wiring in the home is not visible and not reviewed. Once the current occupant's belongings have been removed, it's a good idea to check all outlets with a tester and to look inside cabinets, closets and other obstructed areas before moving in your own belongings. We use a standard electrical tester to check a sample of outlets. While the tester is generally reliable, it can be fooled by certain improper wiring practices, which we cannot detect during a general home inspection. Because electrical defects are safety concerns, we advise the use of a qualified licensed electrician for cost estimates, repairs and upgrades, prior to close.
A. Service Entrance and Panels
Main Electrical Panel Location:   Garage
Sub-Panel Location(s):   N/A
Electrical Main Service:   Underground, 240 Volts
Service Amperage:   200 AMPS
Panel Type:   Breakers, AFCI Breakers
Electric Panel Manufacturer:   CUTLER HAMMER
Comments:
Front of Panel. The main panel box is located at the garage.  The main panel appears to be serviceable at time of inspection.
A. Item 1(Picture)
A. Item 2(Picture)

B. Branch Circuits, Connected Devices and Fixtures
Type of Wiring:   Non Metallic Sheathed Cable (Romex)
Branch Wiring Type:   Copper
GFCI Reset Location(s):   Kitchen, Master Bathroom, Hall Bathroom
AFCI Reset Location(s):   Main Electrical Panel
Comments:
(1) The smoke/CO alarms should be tested upon moving into the home and as a part of a normal maintenance routine as a safety measure.
(2) Damaged light fixture at the exterior. These appear to be low voltage systems and are outside the scope of the inspection. This is for your information.  A qualified contractor should repair or replace as needed..
B. Item 1(Picture)
B. Item 2(Picture)
B. Item 3(Picture)

(3) The carbon monoxide alarm is is needed at living room with gas fireplace. This is a safety concern and is recommended a qualified contractor repair or replace as needed.
(4) Loose hanging receptacle observed at master bathroom, suggest repairing for safety.
B. Item 4(Picture)

Top Table of Contents Bottom
I = Inspected     NI = Not Inspected     NP = Not Present     D = Deficient    
I NI NP D    
 
III.   Heating, Ventilation and Air Conditioning Systems
Our evaluation of heating system(s) is both visual and functional provided power and/or fuel is supplied to the component. Items not listed here as well as things we cannot see, such as utilities, drains, and ducts inside walls, floors and underground are beyond the scope of this inspection. DISMANTLING AND/OR EXTENSIVE INSPECTION OF INTERNAL COMPONENTS OF ANY APPLIANCE, INCLUDING HEATERS AND HEAT EXCHANGERS, IS BEYOND THE SCOPE OF THIS REPORT. THE LOCAL UTILITY COMPANY MAY CONDUCT SUCH AN INSPECTION UPON REQUEST. Our inspection is not a heat engineering or sufficiency review. We suggest you ask the sellers/occupants if any areas of the home do not properly heat or cool. We also suggest you obtain the maintenance history of the furnace as well as receipts for any recent repairs for which a warranty might apply. Clients are encouraged to purchase a home warranty plan, since furnaces can require repair or replacement at any time. Modern furnaces are complicated appliances and should be treated with care. Regular cleaning or replacement of furnace filters is vital to the health of your furnace and can improve the efficiency of attached central air conditioning. We suggest an annual cleaning and safety check by a licensed contractor who is trained in this furnace model. Flammable products should be stored away from the furnace and no fume-producing products such as paint cans should be in the same room. Don't forget that fuel-burning appliances need plenty of oxygen and should not be enclosed without supplying an adequate supply of combustion air. Identifying or testing for the presence of asbestos or other potentially hazardous materials is not within the scope of this report.
A. Heating Equipment
Type of Systems (Heating):   Electric Forced Air Furnace
Energy Sources:   Electric
Number of Heat Systems (excluding wood):   One
Heating Unit Location(s):   Attic
Heat System Brand:   AMERICAN STANDARD
Comments:
(1) Data Tag for Air Handler and Heating Unit.
A. Item 1(Picture)

(2) Debris observed in the overflow pan. Corrections are needed to prevent overflow pan pipe from getting clogged.
A. Item 2(Picture)

(3) Rust was noted in the emergency overflow pan of the AC unit.  At some time in the past, the primary condensate drain line was not properly removing water from the inside portion of the air conditioning system. We are unable to determine if the problem is still current. We recommend consulting sellers for additional information or a licensed heating and air contractor to make any repairs necessary to assure serviceability of the condensate removal system.
A. Item 3(Picture)

(4) Prior Moisture damaged observed on OSB supporting condensate drain line.  Microbial Growth is observed at same location.  Recommend consulting with sellers prior to close about past circumstances and any repairs made. Recommend removal of microbial growth with cleaning solution. A qualified person should repair or replace as needed.
A. Item 4(Picture)

B. Cooling Equipment
Type of Systems (Cooling):   Split Air Conditioning System
Cooling Equipment Energy Source:   Electricity
Number of AC Only Units:   One
AC Unit Location(s):   Exterior
AC System(s) Service:   Entire Home
Central Air Brand:   AMERICAN STANDARD
Comments:
(1) Data Tag for AC unit.
B. Item 1(Picture)

(2) The foam sleeve on the suction line is missing/damaged in area(s) at the condensing unit. Missing foam sleeve insulation on suction line can cause energy loss and condensation. Recommend service or repair as needed.
B. Item 2(Picture)

(3) The ambient air test was performed by using thermometers on the air handler of Air conditioner to determine if the difference in temperatures of the supply and return air are between 14 degrees and 22 degrees which indicates that the unit is cooling as intended. The supply air temperature on your system read 53 degrees, and the return air temperature was 68 degrees. This indicates the range in temperature drop is normal.
B. Item 3(Picture)
B. Item 4(Picture)

C. Duct Systems, Chases and Vents
Ductwork:   Insulated
Comments:
Top Table of Contents Bottom
I = Inspected     NI = Not Inspected     NP = Not Present     D = Deficient    
I NI NP D    
 
IV.   Plumbing System
Our focus in the plumbing portion of the inspection is directed at identifying visible water damage and/or problems. We may not always mention common faults such as stuck stoppers or dripping faucets. If considered important, you should check these items independently. Shut-off valves and angle stops under the kitchen or bathroom sinks and toilets are not turned or tested during the inspection due to the possibility of leaking. All shut-off valves or angle stops should be turned regularly to ensure free movement in case of emergency. The water supply system was tested for its ability to deliver functional water pressure to installed plumbing fixtures and the condition of connected piping that was visible. Our plumbing inspection also consists of checking for functional drainage at all fixtures. Determining whether or not the waste water disposal system is public or private and inspection of waste water disposal systems is not within the scope of this inspection. It is recommended that all public or private waste water disposal systems be reviewed by a licensed plumber or septic system specialist prior to close. Determining the condition or material type used at the main water service from the street to the home is not within the scope of this inspection. A review by a qualified plumber for evaluation of all underground water lines is recommended prior to close. We suggest you obtain the maintenance history for the home's plumbing and obtain receipts for any recent work or for anything for which a warranty may apply
A. Plumbing Supply, Distribution System and Fixtures
Location of Water Meter:   In yard
Location of Main Water Supply Valve:   Not Located
Static Water Pressure Reading:   90 PSI
Water Source:   Public
Plumbing Water Distribution (Inside home):   Copper
Comments:
(1) Water pressure at time of inspection was over 80 psi. The maximum static pressure shall be 80 psi (551 kPa). Elevated pressure levels can cause damage and/or leaks in the plumbing systems or fixtures. Recommend review by licensed plumber for corrections prior to close.
A. Item 1(Picture)

(2) Unable to determine location of main water shut-off, suggest consult with sellers as to location.
(3) Water Meter cover is damaged and water meter is not located in this location.  Recommend repair or replacement as needed.
A. Item 2(Picture)
A. Item 3(Picture)

(4) Water Meter in Front Yard.
A. Item 4(Picture)

B. Drains, Waste and Vents
Plumbing Waste & Vent Pipes:   PVC
Comments:
(1) The tub drain is slow draining in the hall bathroom. Review by qualified plumber is needed for corrections/repairs prior to close.
B. Item 1(Picture)

(2) Condensate drain line is observed in attic. Regular maintenance is needed to prevent buildup and possibly overflowing into attic space. Recommend periodic cleaning.
B. Item 2(Picture)

C. Water Heating Equipment
Water Heater Energy Sources:   Natural Gas
Water Heater Capacity:   Tankless
Water Heater Design Type:   Tankless-Natural Gas
   Extra Info: Rinnai Water Heater
Water Heater Location:   Attic
   Extra Info: Rinnai Water Heater
WH Manufacturer:   RINNAI
   Extra Info: Rinnai Tankless Water Heater
Comments:
(1) Our evaluation of the water heater is both visual and functional provided power and/or fuel is supplied to the unit  Since water heaters are capable of producing scalding temperatures, we suggest you measure your water temperature upon taking occupancy and adjust it to a safe temperature (typically 120 -130 degrees). For further protection, anti-scald faucets are available for sinks, tubs and showers. Due to the possibility of the water heater temperature pressure relief valve leaking after it has been opened, these valves are not tested during the inspection. Manufacturers suggest regular testing to help assure performance. Water heater blankets may void the warranty on some water heaters. Keep all combustibles away from the heater and store no paints or other chemicals in the same room. A spill pan and drain is advised if your heater is located in, adjacent to, or above a finished area. The client is encouraged to consult their agent concerning home warranty options as water heaters can fail at any time and are expensive to repair or replace.
(2) Since a temperature pressure relief (TPR) valve is operated infrequently, it is not unusual for them to leak or break when operated after a period of inactivity. For this reason TPR valves is not tested during a home inspection. We suggest caution when operating TPR valves that have not been tested for a long period of time. When a new water heater is installed a new TPR valve should be installed.
(3) Tankless water heater(s) observed also called instantaneous or on demand water heaters. These water heaters consist of an gas burners or electric heating element enclosed in a small module. Instead of warming a large amount of water stored in a tank, a tankless unit heats only the water that flows through it. When you turn on the hot water faucet, the module senses the change in flow and pressure, and the heating element immediately switches on. Shut off the faucet, the heater stops immediately. The energy savings with this technology can be significant. With conventional water heaters, up to 20 percent of the energy used is wasted because of standby heat loss from the tank and hot water pipes. Tankless models eliminate these losses, resulting in energy savings. The biggest drawback to a tankless water heater is the price; they are much more expensive than a normal storage type water heater. This technology also requires larger gas lines or an additional electrical panel, different exhaust vents and water treatment, creating additional installation expense. Another consideration is the maximum flow rate, if you have a large family, you might not have enough flow capacity to take two showers and run the clothes washer simultaneously. You can avoid those problems by running appliances late at night or having two or more tankless water heaters installed for your specific needs.
(4) Data Tag for Tankless Water Heater.  Current temperature setting is at 120 degrees.
C. Item 1(Picture)
C. Item 2(Picture)

D. Hydro-Massage Therapy Equipment
Comments:
E. Other
Comments:
Top Table of Contents Bottom
I = Inspected     NI = Not Inspected     NP = Not Present     D = Deficient    
I NI NP D    
 
V.   Appliances
Our kitchen appliance inspection is visual and operational in nature of the built-in appliances only. Cooking systems are checked for burner operation but not for calibration, timers, special features or cleaning cycles. Built-in dishwashers are run through a full normal wash cycle to determine if the system is free of leaks and excessive corrosion. Please double-check appliance operation just before closing and re-check for secure cabinets, counters and appliances. Upon occupancy, the client should secure any freestanding oven so it cannot tilt forward when weight is applied to the door. (Most ovens come with directions on how to do this.) Individuals have been injured when sitting on or standing on these doors. Clients are advised to purchase a home protection plan because appliances, including new appliances, can fail at any time, including immediately after the inspection. Older appliances (five years or older), of course, are more prone to failure. Refrigeration units are not within the scope of this inspection and it is recommend that the buyer verify proper working order of any refrigeration units present.
A. Dishwasher
Dishwasher Brand:   GENERAL ELECTRIC
Comments:
B. Food Waste Disposers
Disposer Brand:   NONE
Comments:
C. Range Hood and Exhaust System
Exhaust/Range hood:   NONE
Comments:
This is a recirculating-type fan (does not vent to the exterior). The carbon filter should be changed/cleaned regularly to control odors.
D. Ranges, Cooktops and Ovens
Range/Oven:   GENERAL ELECTRIC
Comments:
A stove anti tip over device has not been installed on this unit. If a child steps on the open door or if a heavy pot is placed on the door, the door acts like a lever forcing the front of the stove down and then back up. Not only will the stove tip and possibly land on your feet, but anything on the range top, such as a pot of boiling water which could cause serious injury. An anti tip bracket can be attached to the bottom of the wall behind the stove by a licensed general contractor. The stove will still slide in and out but will not tip over.
D. Item 1(Picture)
D. Item 2(Picture)
D. Item 3(Picture)

E. Microwave Ovens
Built in Microwave:   GENERAL ELECTRIC
Comments:
F. Mechanical Exhaust Vents and bathroom Heaters
Comments:
G. Garage Door Operator(s)
Auto-opener Manufacturer:   OVERHEAD DOOR
Garage Door Type:   Two automatic
Garage Door Material:   Wood
Comments:
H. Dryer Exhaust System
Comments:
I. Other
Comments:
The smoke/CO alarms should be tested upon moving into the home and as a part of a normal maintenance routine as a safety measure.